The error "Check Detail Read Failed" while trying to open a check/table
on the micros RES 3700 point of sale system. This error is present is
all versions of RES but occurs much less frequently since RES 4.0
This error is an indication that the check has become unreadable in the
database. It can occur if the check is being accessed during a power
failure or some other interruption to the operation of the micros
system.
These checks are unrecoverable and can only be closed in the database.
To proceed you will need to know the check number which is currently causing the error.
Step 1) On the Micros POS server open DBISQL. To do this press Start -> Run -> Type "dbisql" without the quotes.
Step 2) Enter the username and password:
Step 3) Type the following command and replace XXXX with your check number and execute:
chk_seq = Check Sequence number is a unique number
chk_num = Four digit check number used to identify a transaction.
chk_open = True or False. True means the check is open, False means its closed.
Step 4) Make a note of the number in the chk_seq column and type in the following command and replace XXXXXX with the chk_seq number and execute:
The check should now be closed.